Current transformer safety precautions safety precautions care must be taken that the secondary of a current transformer is not disconnected from its load while current is flowing in the primary, as the transformer secondary will attempt to continue driving current across the effectively infinite impedance. Additional protection current transformers at tata steel. Generally, aircore transformers are used when the voltage source has a high frequency above 20 khz. Current transformer basics and the current transformer. Abstractpower transformers can fail from dielectric stresses caused by. Zerosequence current is caused by an unbalanced fault involving ground. Just like the transformer used for stepping down purpose, potential transformer i.
Potential transformer or voltage transformer gets used in electrical power system for stepping down the system voltage to a safe value which can be fed to low ratings meters and relays. Dual dc power supply rectifier using 2 terminal transformer. Voltage transformers of this type are available for use in 50 hz applications for many ratings. Ideal for installation at metering points due to its very high.
Instrument transformers a current transformer is a measurement device designed to provide a current in its secondary coil proportional to the current flowing in its primary. Kod ktf remanence only considered in extra high voltage systems ehv k tfvalues acc. In order to short circuit current transformers and for the purpose of recurrent comparative measurements it is recommended that special terminal block for din rails be used. Electronic voltage and current transformers testing device. Polarity refers to the instantaneous direction of the primary current with respect to the secondary current and is determined by the way the transformer leads are brought out of the case.
The iron core is used to carry the flux linking the secondary current. A current transformer is an instrument transformer, used along with measuring or protective devices, in which the secondary current is proportional to the primary current under normal conditions of operation and differs from it by an angle that is approximately zero. Courtesy siemens current transformers cts are used to convert highlevel currents to a smaller more reasonable level for use as inputs to protection relays and metering equipment. Current transformers cts are used to convert high level currents to a smaller more reasonable level for use as inputs to protection relays and metering equipment. Basic transformer operation can be described by two formulae relating the transformation ratio to. Operation of current transformers janitza electronics. If you connect the outputs in series but one of them is swapped, then you get 0 to the extent the two.
Each of these materials is suitable for certain applications. The following explanation arose from a question from physics. The testing device consists of a precision voltage transformer pvt, precision current transformer pct, data acquisition boards daq1 and daq2, synchronous sampling pulse circuit spc and computer pc. Transformers used for voltage potential measurement steps down the voltage to the level of voltmeter. A current transformer ct is a type of transformer that is used to reduce or multiply an alternating current ac. The above theory is sufficient to give a general view of the problem. Relay class protection current transformers this type of ct includes oilimmersed bussing and resin molded versions. The composition of a transformer core depends on voltage, current, and frequency. A common misconception is that zerosequence current only exists under fault conditions. Ring core cts are available for measuring currents from 50 to 5000 amps, with windows power conductor opening size from 1 to 8. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. Combining 14, 15, and 16 results in an equation for determining the. Does combining two separate transformers double the. Commercially available relays and meters used for protection and metering, are designed for low voltage.
The r 2 is used as the rated secondary burden of pct and as the converter from current to voltage which supplies the daq1daq2 with proper voltage value. Pdf the transient behaviour of a conventional current transformer ct is. Pdf a current transformer model based on the jilesatherton. Used in shelltype transformers stacked by interleaved scheme courtesy of abb tres abb inc. It produces a current in its secondary which is proportional to the current in its primary. Effects of a current transformer s magnetizing current on the driving voltage in selfoscillating converters january 2014 turkish journal of electrical engineering and computer sciences 221.
Instrument transformers application guide abb group. This is called electromagnetic induction because the current in the first coil causes or induces. Transformer basic objective introduce basic transformer theory as it relates to diagnostics. Whenever an alternating current flows through the primary winding, alternating magnetic flux is produced, which then induces alternating current in the. Pdf a current transformer model based on the jiles. Index termscurrent transformer ct, frequency coupling matrix fcm, harmonics. Omar salah elsayed atwa, in practical power system and protective relays commissioning, 2019. A transformer is a passive electrical device that transfers electrical energy from one electrical circuit to another, or multiple circuits. Instrument transformers scale the large values of voltage or current to small. Nov 12, 2019 then, the current flow to filter the pulsating dc voltage of out others bridge diode of the transformer. Then, the current flow to filter the pulsating dc voltage of out others bridge diode of the transformer. Ring core cts are available for measuring currents from 50 to 5000 amps, with windows power conductor opening size from 1 to 8 diameter. Wideband current transducer for measuring ac signals with.
Index termscurrent measurement, current transformer ct. Applications of current transformers current transformers are used extensively for measuring current and monitoring the operation of the power grid. The properties of the magnetic core have a major influence on the performance and behaviour of the ct. When ordering voltage transformers for 50 hz applications, provide an accuracy specification including burden va and power factor. Current transformer definition of current transformer by. These comprise a crossdisconnect terminal with measuring and test equipment, insulated bridges for grounding and short circuiting of the. Current transformers, along with voltage or potential transformers, are instrument transformers. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the actual electrical current flowing in an ac. Current transformer definition is a transformer whose primary carries the whole of an alternating current to be measured or controlled and whose secondary is connected to a measuring or control device. The block diagrams of testing evts and ects are shown in figures 1 and and2, 2, respectively. Voltage transformer or potential transformer theory.
A current transformer has a primary winding, a core and a secondary winding, although some transformers, including current transformers, use an air core. The advantage of this technology is that it will makes the new devices simple, compact, and. B2 current and voltage transformers schneider electric. Optical current transformers offer many benefits compared to conventional current.
Fcms are based on the theory of small signal analysis and are used. Commonly used core materials are air, soft iron, and steel. Basic understanding on current transformer transformer. The operation principle and design equations are dis cussed in detail in this paper. Effects of a current transformers magnetizing current on. High voltage sf6 current transformers image source. From the above equation, by knowing secondary ammeter current and current ratios, we can easily determine the current flowing through the primary which is connected to the main line. These comprise a crossdisconnect terminal with measuring and test equipment, insulated bridges for grounding and short circuiting of the current transformer. Current transformers are designed to provide a scaled down replica of the current in the hv line and isolate the measuring instruments, meters, relays, etc. Within electrical systems, current transformers are essential to ensure the correct functioning and control of equipment and for providing. Transient behaviour of conventional current transformers a current transformer can be represented with the simplified equivalent diagram according to figure 1.
Current transformers current transformers cts provide a simple, inexpensive and yet accurate means of sensing current flow in power conductors. Oct 08, 2016 applications of current transformers current transformers are used extensively for measuring current and monitoring the operation of the power grid. On subtractive polarity transformers the h1 primary lead and the x1 secondary lead will be on the same. These resistors were tested by the precision impedance analyzer wayne kerr 6500b.
Current transformers cts provide a simple, inexpensive and yet accurate means of sensing current flow in power conductors. It causes us can connect directly the positive of 0 volts. Current, voltage and combined transformers, oilpaper or gas insulated up to 800 kv. Primary current range from 5 amp to 5000 amp with secondary current 5a, 1a, or 01. The basics of current transformers nk technologies. Transformer book is still in demand is a tribute to the publishers and to the authors who have carried the torch to light our way for 75 years. Current transformers are commonly used in metering and protective relaying, where they facilitate the safe measurement of large currents. Zerosequence overcurrent elements can be set very sensitive i. Instrument transformers convert signal levels from dangerous high voltage or inconvenient high current, or current at high voltage to levels appropriate for metering. Types of windings the transformer is having two windings. Transient behaviour of conventional current transformers. Primary of this transformer is connected across the phase and ground.
Current transformers perform the following functions. Note also that the transformers will have a polarity. Voltage and current transformers for low primary voltage or current ratings are not. Thus, the output will be symmetric both positive and negative. Like the power transformer, the current transformer also contains a primary and a secondary winding. Morgan lacey in 1925, based on a series of pamphlets entitled transformer abstracts that were. Transient behaviour of conventional current transformers used. A current transformer model based on the jilesatherton theory of ferromagnetic hysteresis article pdf available in ieee transactions on power delivery 151. Whenever the values of voltage or current in a power circuit are too high to permit. Pdf saturation of current transformers and its impact on digital. Effects of a current transformer s magnetizing current on the driving voltage in selfoscillating converters january 2014 turkish journal of electrical. Transformers the current in the first coil is usually called the primary current and the current in the second wire is the secondary current.
A varying current in any one coil of the transformer produces a varying magnetic flux in the transformers core, which induces a varying electromotive force across any other coils wound around the same core. Used in ac system for the measurement of current, voltage, power and energy. Current transformer basics and current transformer theory. Transformer basic objective introduce basic transformer theory as it relates to diagnostics provide a better understanding of the diagnostic test environment. Dec 30, 2018 a voltage transformer theory or potential transformer theory is just like a theory of general purpose step down transformer.
Current transformers ct are used in high voltage hv and medium voltage mv 1 installations to give an image of electrical current to protection relays and units and metering equipment and they are designed to provide a current in its secondary proportional to the current flowing in its primary. Within electrical systems, current transformers are essential to ensure the correct functioning. Compensation of current transformers nonlinearities by tensor. The r 1 is used as the rated secondary burden of pvt. What weve done here is pass an electric current through empty space from one coil of wire to another.
Basic understanding on current transformer free download as powerpoint presentation. In high frequency transformers eddy current losses are reduced by using a core made of a ceramic. Pdf improper selections of current transformers will result in cts saturation during fault conditions which can affect protection relays. Application of optical current transformers in digital. Pdf effects of a current transformers magnetizing current. The basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. All merlin gerin instrument transformers are in conformity with iec standards. A new optical technology was introduced within substations to replace the conventional current and voltage transformers ct and vt. The following explanation arose from a question from. During my apprenticeship i learned about various transformer devices. Jun 02, 2015 as an example, a typical 100 to 5a current transformer has a nominal ratio of single primary turn to 20 secondary turns or 1. Optical technology an overview sciencedirect topics.
Pdf transient behaviour of conventional current transformers. Current transformer definition is a transformer whose primary carries the whole of an alternating current to be measured or controlled and whose secondary is connected to a. Basics, maintenance, and diagnostics vii contents continued page 4. Using a special grade of heattreated grainoriented silicon steel laminations can minimize the hysteresis loss. As an example, a typical 100 to 5a current transformer has a nominal ratio of single primary turn to 20 secondary turns or 1. Current transformer terminal block with short circuit devices. The basic theory regarding accuracy classes, ratio and phase errors etc is the same. A distinction has to be made between a metering class and a protection class current transformer. Current transformers cts basic theory basic formula. Current transformers reduce high voltage currents to a much lower value and provide a convenient way of safely monitoring the.